SHIP
INSPECTION & MONITORING |
CLOSED
OPERATION
Vessels
carrying volatile, flammable, toxic or noxious cargoes
must be provided with fixed closed ullage gauges in all
cargo tanks with local or remote indication.
In addition, in oil and chemical carriers, vapour locks must be fitted on each
cargo tank to consent sampling, dipping, water and temperature detection without
need of opening the cargo tanks. The use of portable hermetic tapes as primary
gauging system will not be accepted. The following fixed closed ullaging devices
are deemed acceptable: mechanically operated floating gauges, electrical capacitance
gauges or electronic probes, ultrasonic and sonic methods.
In case of break down of a fixed gauge, ullage operations should temporarily
be performed by means of portable hermetic tapes through the vapour locks,
provided that correction factors are available and certified so that ship’s
original calibration table may be used.
Correction factors should take into account the difference in height with respect
to the original datum and differences due to the trim and list of the ship.
The number of portable hermetic tapes available on board must be in accordance
with the provisions of IMO MSC/Circ. 551, taking into account the foregoing.
Slip tubes in gas tankers are not deemed to satisfy the requirements for fixed-closed
ullage gauges.